When correctly configured, the Traffic Channel application
is designed to run autonomously without intervention. However, because
of the numerous hardware assets that the program relies on, failures can
occur. Correct operation requires that all components illustrated in the
overview be operating correctly.
The TrafficChannel.exe program writes diagnostic information
to the \TrafficChannel\ErrorLog.txt file as it runs.
This file should be periodically reviewed and should be the first
place to look when the program appears to be running incorrectly.
Note that this file is appended to each time the program is
run, so it should periodically be purged.
Common failure symptoms and possible diagnoses:
- I start the
TrafficChannel.exe program
but it does not appear on the computer.
- Note that the program sleeps or waits to start until the
synchronization value specified in the
sequence configuration file. Verify
that this value is appropriate and that the time you are waiting
is more than the synchronization value.
- The Genie DVE board is memory-usage intensive. No other
desktop applications should be running when
TrafficChanel.exe
is running. If you have exhausted memory, the system should be rebooted.
- I start the
TrafficChannel.exe program
and it appears on the computer monitor but not the
video display.
- Re-seat the physical cable connections to the pigtail on the DVE board
and the video monitor.
- Reset the power on the video monitor.
- Reset the power on the DVE board; that is, shutdown, turn off the
power on the computer, and reboot.
- The video displayed in the DVE swoosh image is not
the correct image for a given map.
- Verify that the video-control computer is operating correctly.
- The video signal displayed in the swoosh of the DVE
appears black or as white noise.
- Disconnect the traffic video signal cable from the DVE board
and connect directly to a video monitor to verify the signal. If
there is no signal coming out of the fiber, contact traffic personnel
at WSDOT to see if there is a known failure
in the video switch or acqusition equipment.
- If the video previews correctly, reset the DVE board.
- The program is running but the segment colors are not changing.
- Verify that your network connection is up by using
ping
or other network software diagnostics.
- Verify that you can reach the ITS generic re-distributor machine by
pinging the machine nova.its.washington.edu.
- Verify that the segmentLogger utility is running and that
the file it creates,
\segmentLogger\sdd.output, is
being updated.
- Error or warning dialogs are displayed when starting the
TrafficChannel.exe program.
- One or more of the configuration files
have been corrupted or incorrectly modified.
- System type error messages typically indicate an OS-related
failure that has led to the exhaustion of resources. Time to re-boot.
Traffic Channel
| ITS UW Home
webmaster@its.washington.edu
(May 11, 1998)